MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
No
|
No
|
A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6.
|
6/26/2026
|
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
Yes
|
No
|
Auxiliary Power fails to bring the car down and open the doors when normal power is removed. UPS indicates a charged.
|
6/26/2026
|
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
Yes
|
No
|
Auxiliary Power (battery lowering) fails to bring the car down and open the doors when normal power is removed. UPS indicates a charged. (Reinspect)
|
8/11/2026
|