MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
interior lights and emergency lights not working
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
x
|
elevator cab lights do not work-needs new fixture 8.11.2.1.1(e)
|
1/7/2021
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
Cab lighting and emergency lighting repaired
|
1/7/2021
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)2
|
x
|
|
1/7/21 Top terminal switch does not spring back.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired)
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
|
8.6.4.15 car emergency light does not work
|
1/7/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
8.11.2.1.1(s) door clutch dragging and striking facia and headers, needs to be realigned
|
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
x
|
8.11.2.1.3(1)(d) both governor and suspension ropes are rusted
|
1/7/2021
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
|
|
governor rope covered in rust
|
7/26/2019
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
x
|
1/7/21 Replace rusty hoist ropes (unchanged since 7/2019 inspection) RED TAG
|
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)8
|
x
|
x
|
1/7/21 Overspeed Governor does not set , repair or replace. RED TAG
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
telephone does not work--reinspect required
|
7/23/2018
|
conversion
|
conversion
|
n/a
|
|
|
emergency light not working
|
|
conversion
|
conversion
|
n/a
|
|
|
car lighting not working
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
no current certificate posted
|
|