Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)4 all non elevator items in machine room need to be removed 9/24/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x B(11)/1.6.1/ : 2-way communication device shall work and give proper location 3/7/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current operating certificate in machine room 9/24/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records G(1)/A17.1-2016:8.6.1.4 :Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil loss log and Fire service testing log, recorded monthly. 9/24/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x G(1)1.18.1/8.6.4.13.1(l): Car Door restrictor shall work. 3/7/2023
MO Minimum : Elevators (H) - Machine Rooms (H)4 H(4)/2.5/8.11.2.1.2(e). Non-elevator related items shall not be stored in Machine Room. (Repeat VIO) 9/24/2024
MO Minimum : Elevators (I) - Pits (I)1 I(1)/5.1/8.11.2.1.5(a) : Excessive debris in pit (combustible hazard) and repair duct cover at ladder. 9/24/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Multiple damaged car call buttons, replace as needed. 9/24/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Provide current state operating certificate in machine room 9/25/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Provide operational pit light 9/25/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Provide operational pit light 9/24/2024
MO Minimum : Elevators (I) - Pits (I)1 Remove dirt and rubbish from pit floor 9/24/2024