Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log No No Test phase 2 fire service 3/25/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current state certificate in machine room 3/25/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency bell shall be operational. 4/14/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Emergency light shall be operational. 4/14/2026
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) Yes No Emergency power shall be tested.
A17.1-2016 : Elevators 2.1 - Access to machine space 2.7.3.3 Yes No Upper machine level guardrail is only 32" in height. Shall be standard height(42") with midrail (21") and toe kick.
A17.1-2016 : Elevators 2.4 - Machine space 8.6.4.8 Machine Room and Machinery Space Yes No Upper machine level lighting shall not be less than 19fc.
A17.1-2016 : Elevators 2.4 - Machine space 2.8.1 Yes No -Disconnects shall be labeled with location of feeder breakers and function.
A17.1-2016 : Elevators 3.11 - Hoistway smoke control 2.1.4 Yes No All ledges greater than 4" shall be properly guarded and/or beveled at 70deg.
A17.1-2016 : Elevators 3.11 - Hoistway smoke control 2.1.4 Yes No Walkway at top of hoistway shall have proper Standard Handrail w/toekick or 70deg Bevel installed.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Yes No Door closing over 30 pounds needs adjusting 6/27/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Emergency light in car not working 6/27/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Repair emergency lights 7/30/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) Yes No Repair car door close button 7/30/2025