MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
No
|
No
|
Counterweight runby does not meet Code Minimum of 6". Runby=1.75"
|
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
No
|
No
|
Missing upthrust roller bearings for proper clearance to door hanger track. @2
|
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
No
|
No
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
12/15/2025
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
No
|
No
|
Post current state certificate in machine room
|
12/15/2025
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.2.1 General Maintenance Requirements Documentation
|
No
|
No
|
Need testing procedures in the MCP located in the machine room
|
12/15/2025
|
|
A17.1-2016 : Elevators
|
5.12 - Car Buffer
|
8.7.3.18
|
No
|
No
|
Adjust car buffer switch
|
12/15/2025
|
|
conversion
|
conversion
|
n/a
|
No
|
No
|
Emergency light/bell not working
|
8/20/2020
|