MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Replace seals on traction driving machine, leaking fluid.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
A copy of the MCP shall be kept in the machine room for each elevator
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
A copy of the MCP shall be kept in the machine room for each unit.
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A copy of the current state certificate shall be displayed in the machine room
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A copy of the current state operating certificate shall be on display in the machine room
|
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)8
|
x
|
x
|
Test car safeties with rated load at rated speed. Red tagged, Re-inspection required
|
9/28/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
x
|
Traction driving machine will not pick rated load due to suspension ropes loosing traction on machine sheave. Red tagged, removed from service. Re-inspection required
|
9/28/2022
|
MO Minimum : Elevators
|
(D) - Brakes
|
(D)1
|
x
|
x
|
Traction machine brake hub is off center causing vibration and brake to overheat, need to replace brake. Red-tagged, removed from service. Re-inspection required
|
10/5/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
x
|
Re-inspection of drive machine brake, unit will not run (keeps tripping overload) Could not test brake, elevator still Red-tagged, Re-inspection required
|
10/12/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.11 Runby (Re-Inspection)
|
x
|
|
Hoist ropes shall be shortened, the counterweight is touching the springs when the car is at the top floor. Re-inspection required within 30 days
|
9/1/2023
|