Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Replace seals on traction driving machine, leaking fluid.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A copy of the MCP shall be kept in the machine room for each elevator
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)8 x x Test car safeties with rated load at rated speed. Red tagged, Re-inspection required 9/28/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements x Traction driving machine will not pick rated load due to suspension ropes loosing traction on machine sheave. Red tagged, removed from service. Re-inspection required 9/28/2022
MO Minimum : Elevators (D) - Brakes (D)1 x x Traction machine brake hub is off center causing vibration and brake to overheat, need to replace brake. Red-tagged, removed from service. Re-inspection required 10/5/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A copy of the MCP shall be kept in the machine room for each unit.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x x Re-inspection of drive machine brake, unit will not run (keeps tripping overload) Could not test brake, elevator still Red-tagged, Re-inspection required 10/12/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.11 Runby (Re-Inspection) x Hoist ropes shall be shortened, the counterweight is touching the springs when the car is at the top floor. Re-inspection required within 30 days 9/1/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state certificate shall be displayed in the machine room
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be on display in the machine room