Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a No No Fire extinguisher needs to be serviced 2/4/2020
conversion conversion n/a No No Both rear and front door operators need the torque adjusted above 30. 2/4/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No The battery back–up lowering device was tested and did not operate as designed, the elevator failed to return to a lower floor and open its doors. Repair the device to operate as it is designed. 3/14/2024
A17.1-2016 : Elevators 3.2 - Car top light and outlet 8.11.3.1.3(b) No No The car top inspection light/fixture switch did not operate. Repair light/fixture switch for proper operation and illumination for maintenance/emergency personnel. 3/14/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Car top light not working properly, repair as needed. 3/14/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing No No This elevator is equipped with an overspeed valve. A category 5 test shall be performed on the overspeed valve on or before the next annual inspection.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No Replace missing in car capacity signage.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No Need to replace missing in car capacity signage
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Battery backup lowering unit not working correctly. Repair/ replace as needed. 8/4/2023