Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No phone didnt work
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone dials out but does not connect. 6/22/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes Yes Fire initiating devices have been installed but need to be tested with an inspector present. 6/16/2022
MO Minimum : Elevators (S) - Fire Service (S)1 Yes Yes Install smoke sensing devices at elevator lobbies except the main designated landing. The smoke sensing devices, when activated, shall return elevator to the main designated landing. 6/13/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) No No Keep the correct and up to date wiring diagrams for the elevator in the machine room. 6/20/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) No No Keep up to date wiring diagrams in the machine room. The wiring diagrams on site are not the correct ones for the elevator. 6/1/2022
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal No No No audible signal during fire recall 6/20/2023
MO Minimum : Elevators (S) - Fire Service (S)1 Yes Yes Remove newly installed fire initiating device at the main landing. Per A17.1-1978 rule 211.3a2 6/16/2022
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No Remove non-elevator related material from machine room. (Gallons of paint-water hose-water sprinkler-snow shovel) 6/20/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No State operating certificate not displayed 6/20/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.11.1 Firefighters' Emergency Operation & Documentation No No Test and log firefighter operation monthly 6/1/2022
MO Minimum : Elevators (I) - Pits (I)1 No No Water accumulated in the elevator pit from the broken water line from the drinking fountain shall be removed. 3/12/2026