Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)1 No No Steps to machine room deteriorating, repair as necessary. 10/5/2024
MO Minimum : Elevators (H) - Machine Rooms (H)1 No No provide a safe means of access to an from the roof to get to the machroom what is ther is very dangerous.
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No machine room door not self closing or self locking provide fire rated self locking an self closing door
A17.1-2016 : Elevators 2.29 - Car and counterweight safeties 8.6.4.19.2 Yes Yes winding drum safeties had over 6ft of pull out to set safeties 42 ins is allowed
A17.1-1996 : Elevators 3.27 - Crosshead data plate 207.3 No No Crosshead data tag needs to specify capacity of 1500# 9/8/2023
A17.1-1996 : Elevators 3.9 - Floor and emergency identification numbering 211.9 No No Identify the inside of hoistway doors with a numeral 9/8/2023