Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The pit lighting shall be operational. 11/30/2020
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)4 Leak in machine room hydraulic supply line shall be repaired. 11/30/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door shall be self-closing, self-locking, and shall be operable from the interior space without the use of a key. 11/30/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 Car top emergency exit shall be hinged or otherwise attached to the car. 11/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams Wiring diagrams shall be available in the machine room. 11/30/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The pit lighting shall be operational. 11/30/2020
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)4 Leak in machine room hydraulic supply line shall be repaired. 11/30/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door shall be self-closing, self-locking, and shall be operable from the interior space without the use of a key. 11/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. 11/30/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 11/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams Wiring diagrams shall be available in the machine room. 11/30/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. 11/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 8/30/2021
MO Minimum : Elevators (A) - Hoistways (A)16 All electrical wiring in the hoistway shall be enclosed in metal conduit, flexible conduit, or metal raceway, or be in compliance with NFPA 70. 9/20/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Compliant/required documentation & MCP shall be kept in equipment room (neat/organized and not on car top) including wiring diagrams, oil log, and fire service log, recorded monthly. Not present in the machine room at this time.
MO Minimum : Elevators (I) - Pits (I)1 The pit shall be kept clean. Remove excess debris.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 Car top emergency exit shall be hinged or otherwise attached to the car. 11/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams Wiring diagrams shall be available in the machine room. 11/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x In car emergency telephone shall be operational. 4/17/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x 2-way communication device shall work, with and without main power, and give proper location. 11/16/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x The in car emergency bell does not work. 9/20/2022