Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure No No Exposed wiring on top of car 10/20/2020
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) No No FFS Phase II hold not working 10/20/2020
MO Minimum : Elevators (H) - Machine Rooms (H)1 No No Keep access to machine room stairs clear, and unobstructed. 12/20/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Provide a self closing, self locking mechanism for machine room door. 12/20/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)9 Capacity Plate No No No rated load visible in cab
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No Needs Phase I signage in hall
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) Yes No Needs car door restictors
MO Minimum : Elevators (F) - Electrical Switches (F)2 Yes No The car does not reach the upper final limit switch. The runby is insufficient, shorten the ropes. 6/9/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not working. 12/6/2023