Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (I) - Pits (I)1 No No -All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. The sump pump is not working. There is a water/oil mixture in the pit that needs to be pumped out. 5/14/2026
A17.1-2016 : Elevators 2.32 - Control Valve 8.6.5.5.1 Examination and Maintenance Yes No -The control valve is leaking oil from the bottom. Correct the oil leak.
MO Minimum : Elevators (I) - Pits (I)1 No No All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. The sump pump is not working. There is a water/oil mixture in the pit. 5/14/2026
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing No No Overspeed valves, where provided, shall be inspected and tested to verify that they will stop the car, traveling down with rated load every 5 years. 5/14/2026
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Phone in elevator cab does not work. 9/12/2018
MO Minimum : Elevators (I) - Pits (I)1 No No Remove water/oil slurry from pit 5/14/2026
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Telephone in car doesn't work. Phone line dead to elevator controller. 10/1/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts No No The bottom beveled edge of the top hoistway door has broken off and needs to be repaired 5/14/2026