ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.18 - Restricted opening of car or hoistway doors
|
2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection)
|
x
|
|
Car door restrictor does not function
|
5/16/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.18 - Restricted opening of car or hoistway doors
|
2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection)
|
x
|
|
Car door restrictor does not function.
|
11/19/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.16 - Rated load, platform area, and data plate
|
2.16.3.1 Capacity Plates
|
|
|
Install 2500 LBS Capacity plate inside the elevator. The existing capacity plate does not correspond with crosshead data plate.
|
6/21/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.7.2 Periodic Test Record (Test Tags)
|
|
|
Install and date period test tag
|
11/13/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.16 - Rated load, platform area, and data plate
|
2.16.3.1 Capacity Plates
|
|
|
Install capacity plate inside the elevator "2000 lbs Capacity"
|
11/13/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
8.11.2.1.3(r)
|
|
|
Install covers on 4x4 electrical gangboxes at top of hoistway
|
2/22/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
8.11.2.1.3(r)
|
|
|
Install covers on conduit pullboxes located near top of hoistway.
|
11/19/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.27 - Crosshead data plate
|
8.11.2.1.3(k)
|
|
|
Install suspension rope data tag to ropes
|
2/22/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.1 - Access to machine space
|
2.7.3.4
|
|
|
Machine room access door shall be self-closing
|
11/13/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.9 - Guarding of exposed auxiliary equipment
|
2.10.1
|
|
|
Provide guarding of machine drive sheave and hoist ropes.
|
11/19/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.11.1
|
|
|
Test and log firefighter operation monthly
|
11/19/2021
|