Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A copy of the current operating certificate shall be displayed in the machine room 5/29/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A copy of the current operating certificate shall be displayed in the machine room 6/3/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No All water and gas conveying devices shall be separated from the elevator machine room 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No All water and gas conveying devices shall be separated from the elevator machine room 5/29/2026
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Connect fire alarm initiating devices to the elevator controller 5/11/2023
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Connect fire alarm initiating devices to the elevator controller 2/27/2024
MO Minimum : Elevators (A) - Hoistways (A)3 No No Door closing device at bottom landing shall close hoistway door when elevator is not at the landing 5/29/2026
MO Minimum : Elevators (A) - Hoistways (A)3 No No Door closing device shall close door when the elevator is not at the landing 5/29/2026
MO Minimum : Elevators (A) - Hoistways (A)3 No No Door closing device shall close door when the elevator is not at the landing 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Fire extinguisher dated 2017. Provide a Fire extinguisher with a current service date 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Fire extinguisher dated 2017. Provide a Fire extinguisher with a current service date 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Fire extinguisher dated 2017. Provide a Fire extinguisher with a current service date
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door shall be self closing and self locking 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door shall be self closing and self locking 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No Machine room lighting shall be 10ft candles through out. Measured at the floor 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No Machine room lighting shall be 10ft candles through out. Measured at the floor. 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Need to replace missing handrail 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Provide a 5gal maximum container in the pit to collect packing leakage 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams No No Provide current and up to date prints in the machine room 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams No No Provide current and up to date prints in the machine room 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No No Provide maintenance control program 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No No Provide maintenance control program 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No Provide maintenance logs 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No Provide maintenance logs 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)7 No No Provide testing of shunt trip disconnect activated by the machine room heat detector 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)7 No No Provide testing of shunt trip disconnect activated by the machine room heat detector 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)7 No No Provide testing of shunt trip disconnect activated by the machine room heat detector 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)7 No No Provide testing of shunt trip disconnect activated by the machine room heat detector
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) No No Provide up to date wiring diagrams in the machine room
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) No No Provide up to date wiring diagrams in the machine room 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Remove cable equipment from the elevator machine room 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Remove cable equipment from the elevator machine room
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Remove cable equipment from the elevator machine room 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Remove cable equipment from the elevator machine room 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Remove compressor from elevator Machine Room - Blocking entrance 5/29/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Remove compressor from elevator Machine Room - Blocking entrance 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Repair inoperative emergency phone 5/11/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Replace missing in car handrail 5/29/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Replacement Parts::Replace missing in car handrail 5/29/2026
MO Minimum : Elevators 11 CSR 40-5.130 Variances (2)(B) Variance Inspection No No Required Variance Inspection required 5/29/2026