Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The state operating certificate in the machine room expired 2011, update with a new copy when received from the state annually
MO Minimum : Elevators (I) - Pits (I)1 Oil on pit floor, clean pit floor
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance Replace packing, leaking all over the pit
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Fire service phase 1 keyswitch collar markings are gone, replace chicklet so markings can be read
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate in the machine room expired in 2011, update with current copy when received from the state of Missouri
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates fire service phase 1 keyswitch collar marking are gone, replace collar so marking can be read
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Provide updated permit in a displayable location
MO Minimum : Elevators (S) - Fire Service 211.8 Switch Keys Replace illegible fire service phase 1 bezel
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Missing fire egress signage
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Owner to provide updated monthly fire service logs
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal Missing fire service jewel cover on car operating panel
MO Minimum : Elevators (I) - Pits (I)1 Remove oil absorbent pads from the pit floor
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Missing Fire Service Phase 1 instructions at main egress
conversion conversion n/a repair or replace elevator phone, it rings once and then disconnects before security can answer
conversion conversion n/a replace the phase 1 keyswitch chicklet, the words can not be read for on, off, bypass or fire service
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate a new copy of the state operating certificate is to be posted in the machine room every year
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log post a monthly fire service test log in the machine room and fill it out monthly
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x repair the emergency phone, it has a dial tone, it dials a number, it rings once and then hangs up 10/22/2020
MO Minimum : Elevators (S) - Fire Service (S)1 x x replace fire service phase 1 instruction chicklet, no longer able to read the markings "on, off, bypass" 10/22/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) the emergency phone rings once and then hangs up before allowing communication 1/4/2023