ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.17 - Drive machine brake
|
2.16.8
|
Yes
|
No
|
The drive machine brake shall be tested.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.19 - Car Ride
|
2.23
|
Yes
|
No
|
Verify that the car levels properly with all floors.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.3 - Operating control devices
|
2.26.1.1
|
Yes
|
No
|
Properly secure the car operating panel cover.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.15 - sign and operating device symbols
|
2.26.12
|
Yes
|
No
|
Patch holes where prior direction arrows were located on various floors.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.26.2.7
|
Yes
|
No
|
The pit stop switch shall be located approximately 18" above floor level and adjacent to the pit ladder.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.26.2.7
|
Yes
|
No
|
The pit stop switch shall have a cover installed.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.2-2.27.8
|
Yes
|
Yes
|
All phases of fire service shall be tested, as well as, all initiating devices.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.1 - Access to machine space
|
2.7.3.4
|
Yes
|
No
|
The machine room door shall be self-closing and self-locking.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.3 - Lighting and receptacles
|
2.7.5.1
|
Yes
|
No
|
The machine room lighting shall be 10 foot-candles at the floor level.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.9 - Buffers and emergency terminal speed limiting devices
|
8.10.2.2.5(c)
|
Yes
|
No
|
Car and counterweight buffers shall be tested.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.11 Periodic Inspection and Test.
|
Yes
|
No
|
2.12.3 - There is insufficient work space in front of the controller. Currently 33" to other controller and 21" to MG set. The clearance shall be 48".
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
The person receiving the emergency phone call from the elevator shall be able to identify the location the call is originating from.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.8 - Door closing force
|
8.11.2.1.1(h)
|
Yes
|
No
|
Door closing force shall be tested.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.15 - sign and operating device symbols
|
8.11.2.1.1(o)
|
Yes
|
No
|
Patch holes in the hoistway at 6th & 28th floors.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
8.11.2.1.5(j)
|
Yes
|
No
|
The car safeties shall be tested.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
Yes
|
No
|
Provide a code compliant MCP including onsite documents.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
4.5 - Access to Hoistway
|
8.6.4.14 Hoistway Access Switches
|
Yes
|
No
|
The bottom hoistway access switch shall limit movement to the point where the bottom of the platform guard is even with hoistway entrance.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.5 - Housekeeping
|
8.6.4.8 Machine Rooms and Machinery Spaces
|
Yes
|
No
|
Materials not used for operation of elevators shall not be in the machine room. (Non used controllers, MG sets, and various items)
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.14 - Code data plate
|
8.9
|
Yes
|
No
|
Provide a code compliant code data tag.
|
|