Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.18 - Restricted opening of car or hoistway doors 8.6.4.13.1(l)(Door Restrictor) Yes No Door restrictor inoperable. Re-inspection required 4/21/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Elevator has a unit above it that is dripping liquid on top of the elevator machine. All equipment shall be guarded from anything above it conveying liquid, gas or vapor 4/21/2026
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No Elevator cab lights have egg crate type ceilings that do not provide protection in case a bulb were to shatter. Replace ceiling tiles or place tube sleeves on light bulbs 4/21/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No State operating certificate is outdated 4/21/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Elevator has a unit above it that is dripping liquid on top of the elevator machine. All equipment shall be guarded from anything above it conveying liquid, gas, or vapor 4/21/2026