Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency Phone in car fails to establish two-way communication
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Provide 2.5 foot candles of lighting in elevator cab. C-5 11/1/2018
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Phone in elevator cab does not work. 9/7/2018
A17.1-2016 : Elevators 3.17 - Door and gate equipment 8.6.4.13 x For vertical power closing doors with momentary or automatic closing. A warning bell or other audible signal shall be provided on the car which shall start to sound at least 5 seconds prior to the time the car door or gate starts to close and shall continue to sound until the hoistway door is substantially closed.
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.2-211.8 x x Phase I recall - When car returns to recall floor, the doors can still be opened and closed. Doors should open and remain open 5/30/2019
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.2-211.8 x x Fire service Phase II - Doors open and close automatically. Should be constant pressure open and close 5/30/2019