MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Unit relevels too frequently, stand test shows possible check valve issues. Investigate, repair as needed.
|
5/11/2023
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
|
|
Machine room lighting needs to be repaired
|
5/11/2023
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Pit shall be kept dry. Remove rust from pit equipment , repaint, investigate/repair water leak. Jack casing should be capped. Sump pump has failed, 6" water in pit.
|
5/11/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired)
|
5/11/2023
|