Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No The emergency car lighting is not operational.The fixture shall be repaired to operate. Reinspection required. 6/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No The elevator ADA telephone inside the elevator is not working properly. Check and repair the programming of this phone for proper operation and passenger safety. Reinspection required. 6/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Yes No The car door restrictor device shall be adjusted so that it will properly catch and restrict opening of the car doors to a maximum of 4 inches when the car is away from the landing zone. Reinspection is required. 6/21/2022
MO Minimum : Elevators (I) - Pits (I)1 No No Pit shall be clean of debris 6/22/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No There shall be maintenance records kept in the elevator machine room accessible to the inspector depicting dates and descriptions of maintenance tasks performed, callbacks, examinations, tests, adjustments, replacements and wiring diagrams. This shall be in accordance to the requirements in the Maintenance Control Program. 7/5/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) No No Unusual testing procedures not outlined in A17.2 shall be present and accessible according to this code section. These include but not limited to procedures for tests, periodic inspections, maintenance, replacements, adjustments, and repairs for traction-loss detection means, broken-suspension-member detection means, residual-strength detection means, and related circuits. 7/5/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No No A written Maintenance Control Program (MCP) shall be in place to maintain the equipment in compliance with the requirements of 8.6.The MCP shall include but not limited to examinations, tests, cleaning, lubrication, and adjustments to applicable components at regular intervals. 7/5/2022
A17.1-2016 : Elevators 2.19 Gears, Bearings, and Flexible Couplings 8.11.2.1.2(v) No No A grease seal on the drive machine is leaking excessively and shall be replaced. 7/5/2022
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor. 7/5/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No The cab ceiling is of the open egg-crate type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. 7/5/2022
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) Yes Yes Hoist ropes are showing signs of wear and rouge. Two hoist ropes are at maximum stretch. Red-tagged elevator until hoist ropes are replaced and re-inspected. 1/10/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Emergency light is out. Re-inspection required 1/10/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No A grease seal on the drive machine is leaking and needs to be replaced 2/2/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) No No No documentation for procedures and tests 2/2/2024
MO Minimum : Elevators (I) - Pits (I)1 No No Pit needs to be cleaned of debris 2/2/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Emergency light is out. Re-inspection required 2/2/2024
A17.1-2016 : Elevators 2.14 - Code data plate 8.9 Yes No Provide alteration code data plate in machine room permanently marked. 5/26/2026
A17.1-2016 : Elevators 2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) 8.4 Yes No Test counterweight seismic device. 5/26/2026
A17.1-2016 : Elevators 2.6 - Ventilation 2.7.9.2 Yes No Provide working hvac system in elevator machine room to keep temperature within elevator equipment operating range. 5/26/2026
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3 Yes Yes Test all smoke and heat detectors connected to elevator controller. Smoke detectors, when activated shall recall elevator to primary or alternate landing. Also test phase 1 and 2 fire service key operation. 5/26/2026
A17.1-2016 : Elevators 1.17 - Standby power operation 2.27.2 Yes No Test elevator for operation on emergency power. 5/26/2026
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2.5 Sump Pump Required/Capacity (Re-Inspect) Yes No Provide sump pump in elevator pit. 5/26/2026
A17.1-2016 : Elevators 3.20 - Governor rope 2.18.5 Yes No Provide governor rope data tag on governor rope. 5/26/2026
A17.1-2016 : Elevators 4.1 - Car platform guard 2.15.9 Yes No Equip elevator with platform guard no less than 48 “ long. 5/26/2026
A17.1-2016 : Elevators 1.6 - Car emergency signal 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Unable to complete smoke detector test due to fire service reset not working properly, need to perform smoke test. Re-inspection required 5/27/2026
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No Fire service will not reset from fire service to normal operation. 5/27/2026
A17.1-2016 : Elevators 1.17 - Standby power operation 2.27.2 Yes No Need to perform generator test. Re-inspection required 5/27/2026