Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) No No Unusual testing procedures not outlined in A17.2 shall be present and accessible according to this code section. These include but not limited to procedures for tests, periodic inspections, maintenance, replacements, adjustments, and repairs for traction-loss detection means, broken-suspension-member detection means, residual-strength detection means, and related circuits. 7/5/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No There shall be maintenance records kept in the elevator machine room accessible to the inspector depicting dates and descriptions of maintenance tasks performed, callbacks, examinations, tests, adjustments, replacements and wiring diagrams. This shall be in accordance to the requirements in the Maintenance Control Program. 7/5/2022
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.11.2.1.5(a) No No The elevator pit light was missing a light guard on the day of inspection, reinstall light guard in the pit. 7/5/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No The cab ceiling is of the open egg-crate type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. 7/5/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) No No Procedures for inspections and tests 2/2/2024
MO Minimum : Elevators (I) - Pits (I)1 No No Pits shall be cleaned of debris 2/2/2024
MO Minimum : Elevators (I) - Pits (I)1 No No Pits shall be clean of debris 6/22/2022
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No Fire service will not reset from fire service phase I to normal operation 5/27/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No No A written Maintenance Control Program (MCP) shall be in place to maintain the equipment in compliance with the requirements of 8.6.The MCP shall include but not limited to examinations, tests, cleaning, lubrication, and adjustments to applicable components at regular intervals. 7/5/2022
A17.1-2016 : Elevators 1.6 - Car emergency signal 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Unable to complete smoke detector test due to fire service not re-setting. Re-inspection required 5/27/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No The emergency light does not illuminate when normal power is removed 11/8/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No The elevator ADA telephone inside the elevator is not working properly. Check and repair the programming of this phone for proper operation and passenger safety. Reinspection required. 6/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Yes No The car door restrictor device shall be adjusted so that it will properly catch and restrict opening of the car doors to a maximum of 4 inches when the car is away from the landing zone. Reinspection is required. 6/21/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Testing of the back-up generator to run the elevators. Re-inspection required 2/2/2024
A17.1-2016 : Elevators 1.17 - Standby power operation 2.27.2 Yes No Test elevator for operation on emergency power. Re-inspection required 5/26/2026
A17.1-2016 : Elevators 2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) 8.4 Yes No Test counterweight seismic device. Re-inspection required 5/26/2026
A17.1-2016 : Elevators 2.6 - Ventilation 2.7.9.2 Yes No Provide working HVAC system in elevator machine room to keep temperature to keep elevator equipment operating range. 5/26/2026
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2.5 Sump Pump Required/Capacity (Re-Inspect) Yes No Provide sump pump in elevator pit. Re-inspection required 5/26/2026
A17.1-2016 : Elevators 3.20 - Governor rope 2.18.5 Yes No Provide governor rope data tag on governor rope 5/26/2026
A17.1-2016 : Elevators 2.14 - Code data plate 8.9 Yes No Provide alteration code data plate in machine room permanently marked 5/26/2026
A17.1-2016 : Elevators 4.1 - Car platform guard 2.15.9 Yes No Platform guard no less than 48" long 5/26/2026
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Need to test all smoke and heat detectors connected to the elevator controller. Smoke detectors, when activated shall recall elevator to primary or alternate landing. Also test phase I and 2 service key operation. Re-inspection required 5/26/2026
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Need testing of backup generator to run the elevator 1 & 2. Re-inspection required 5/27/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.11 Runby (Re-Inspection) Yes No Cables shall be shortened. Car final limit was adjusted so final limit is sctivated unitl cables are shortened. Cables need to be shortened in 15 days or less. Counterweight was striking the spring buffer not allowing the final limit to stay engaged. Re-inspection required 2/2/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.11 Runby (Re-Inspection) Yes No Cables need to be shortened. Car final limit was adjusted so final limit is activated until cables are shortened. Counterweight was striking the spring buffer not allowing the final limit to stay engaged. Re-inspection required 5/27/2026