Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A17.1 - 2016 8.6.1.2.2 MCP ONSITE DOCUMENTATION NEEDED TO FULFILL 8.6.1.1.1(b) & ONSITE MAINTENANCE RECORDS (see 8.6.1.4.1) THAT RECORD THE COMPLETION OF ALL ASSCIATED MAINTENANCE TASKS SPECIFIED IN 8.6.1.4.19(a) NO WRITTEN DOCUMENTATION FOR MAINTENANCE IN MACHINE ROOM OR WHERE TO RETRIVE IT FROM. (OIL USAGE , FIRE SERVICE, MAINTENANCE & CALL BACK LOGS) (OTIS TO PROVIDE)
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing OSV NOT TAGGED OR SEALED, TEST BEFORE NEXT INSPECTION.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing A17.1 - 8.6.5.16.5 OVERSPEED VALVE NOT SEALED, PERFORM REQUIRED 5 YR OSV TESTING PRIOR TO NEXT INSPECTION PER MISSOURI DEPARTMENT OF FIRE SAFETY/ ELEVATOR SAFETY DIVISION OTIS TO SCHEDULE)