Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 No No repair elevator cab lights, they are not staying on 1/10/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1206.7 No No Perform monthly fire service test and post a log in the machine room 7/21/2020
A17.1-1996 : Elevators 1.14 - Ventilation 204.2c No No repair duct work for car top a/c unit, ensure the a/c unit is in working order, glass back elevator exposed to direct sunlight 7/21/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No The building shall post the operating certificate in the elevator equipment room, and it needs to be updated with a new copy every year. 7/14/2021
A17.1-2016 : Elevators 1.14 - Ventilation 8.11.3.1.1(n) No No make sure a/c unit on the car top is in working order 5/31/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No the fire service phase 2 keyswitch collar markings cannot be read, replace collar 5/31/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No in car stop keyswitch collar marking cannot be read, replace collar 5/31/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars No No Clean the car top 7/18/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No Clean unexposed hoistway sills 7/18/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Provide updated permit in the cab or other specified location 7/18/2025
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(a)(1) No No Provide updated maintenance task log 7/18/2025
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) No No Machine room fire extinguisher inspection tag is expired, it was due for annual inspection in February 2026.
A17.1-1996 : Elevators 5.11 Plunger and Cylinder 1206.5b(5) Oil Leakage Collection No No Jack head drain is clogged with lint and the oil is overflowing the head and running down the side of the jack.
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 1206.2a (Pits and Hoistways) No No Clean up oil on pit floor
A17.1-1996 : Elevators 1.15 - sign and operating device symbols 1001.2(a)(15) No No In case of fire use stairs signs missing on top and bottom landings
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No the state operating certificate in the machine room is to be updated every year 5/31/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars No No Clean off car top, air conditioning unit that hasn't worked for years should be replaced with something that works. (glass back elevator) 10/24/2024
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Elevator would not return to recall floor when the phase 2 was turned off 2/26/2025
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No replace the emergency phone, it did not work and the phone line tested good 3/18/2020
MO Minimum : Elevators (S) - Fire Service (S)1 Yes Yes adjust nudging speed, doors will not close when keyed off of fire service phase 2 to return to the recall floor 8/30/2022