Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (S) - Fire Service (S)1 x x adjust nudging speed, doors will not close when keyed off of fire service phase 2 to return to the recall floor 8/30/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Clean off car top, air conditioning unit that hasn't worked for years should be replaced with something that works. (glass back elevator) 10/24/2024
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Elevator would not return to recall floor when the phase 2 was turned off 2/26/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates in car stop keyswitch collar marking cannot be read, replace collar 5/31/2022
A17.1-2016 : Elevators 1.14 - Ventilation 8.11.3.1.1(n) make sure a/c unit on the car top is in working order 5/31/2022
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1206.7 Perform monthly fire service test and post a log in the machine room 7/21/2020
A17.1-1996 : Elevators 1.14 - Ventilation 204.2c repair duct work for car top a/c unit, ensure the a/c unit is in working order, glass back elevator exposed to direct sunlight 7/21/2020
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 repair elevator cab lights, they are not staying on 1/10/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x replace the emergency phone, it did not work and the phone line tested good 3/18/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The building shall post the operating certificate in the elevator equipment room, and it needs to be updated with a new copy every year. 7/14/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates the fire service phase 2 keyswitch collar markings cannot be read, replace collar 5/31/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate in the machine room is to be updated every year 5/31/2022