Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The building shall post the operating certificate in the elevator equipment room, and it needs to be updated with a new copy every year. 7/14/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate in the machine room is to be updated every year 5/31/2022
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)(12) - when fire service phase 2 was keyed to the off position with the doors open at a floor other than the designated level, the elevator did not go back on phase 1 and return to the designated level 1/9/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1206.7 Perform monthly fire service test and post a log in the machine room 7/21/2020
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 the emergency light battery is dead and needs to be replaced 1/10/2020
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x emergency lights did not come on, repair emergency lights 3/13/2024
A17.1-1996 : Elevators 1.14 - Ventilation 204.2c the air conditioner provided for this observation elevator is not working, there shall be a minimum air handling capacity to provide one air change per minute based on net inside car volume, with auxiliar power source 10/24/2024
A17.1-1996 : Elevators 1.14 - Ventilation 204.2c repair car top a/c unit, it is in peices, needs to work for glass back elevator exposed to direct sunlight 7/21/2020
A17.1-2016 : Elevators 1.14 - Ventilation 8.11.3.1.1(n) top of car air condition unit is not in working order, repair a/c unit 5/31/2022
MO Minimum : Elevators (H) - Machine Rooms (H)4 Water on the machine room floor after storm, repair leak 10/24/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x emergency light did not come on, the alarm bell did work 5/31/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates can not read the markings on the fire service phase 2 keyswitch collar, replace the collar 5/31/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates can not read the markings on the in car stop keyswitch collar, replace the stop switch collar 5/31/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Clean off car top, air conditioning unit that hasn't worked for years should be replaced with something that works. (glass back elevator) 10/24/2024