MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
can not read the markings on the fire service phase 2 keyswitch collar, replace the collar
|
5/31/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
can not read the markings on the in car stop keyswitch collar, replace the stop switch collar
|
5/31/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.9 Cleaning of Top of Cars
|
|
|
Clean off car top, air conditioning unit that hasn't worked for years should be replaced with something that works. (glass back elevator)
|
10/24/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
emergency light did not come on, the alarm bell did work
|
5/31/2022
|
A17.1-1996 : Elevators
|
1.5 - Car lighting and receptacles
|
204.7a (3)(a) Standby Illumination in the car. (Re-Inspection)
|
x
|
|
emergency lights did not come on, repair emergency lights
|
3/13/2024
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1206.7
|
|
|
Perform monthly fire service test and post a log in the machine room
|
7/21/2020
|
A17.1-1996 : Elevators
|
1.14 - Ventilation
|
204.2c
|
|
|
repair car top a/c unit, it is in peices, needs to work for glass back elevator exposed to direct sunlight
|
7/21/2020
|
A17.1-1996 : Elevators
|
1.14 - Ventilation
|
204.2c
|
|
|
the air conditioner provided for this observation elevator is not working, there shall be a minimum air handling capacity to provide one air change per minute based on net inside car volume, with auxiliar power source
|
10/24/2024
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
The building shall post the operating certificate in the elevator equipment room, and it needs to be updated with a new copy every year.
|
7/14/2021
|
A17.1-1996 : Elevators
|
1.5 - Car lighting and receptacles
|
204.7
|
|
|
the emergency light battery is dead and needs to be replaced
|
1/10/2020
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
the state operating certificate in the machine room is to be updated every year
|
5/31/2022
|
A17.1-2016 : Elevators
|
1.14 - Ventilation
|
8.11.3.1.1(n)
|
|
|
top of car air condition unit is not in working order, repair a/c unit
|
5/31/2022
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
Water on the machine room floor after storm, repair leak
|
10/24/2024
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1001.2(d)(12) -
|
|
|
when fire service phase 2 was keyed to the off position with the doors open at a floor other than the designated level, the elevator did not go back on phase 1 and return to the designated level
|
1/9/2020
|