MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)8
|
|
|
Multiple exposed wires running through machine room
|
10/23/2019
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room door shall be self closing and self locking
|
10/23/2019
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)3
|
|
|
Bottom floor sill bowed not allowing hoistway door to be self closing
|
10/23/2019
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
Emergency light in car doesn't work
|
10/23/2019
|
MO Minimum : Elevators
|
(N) - Guide Rails
|
(N)1
|
|
|
Reduced running clearance. Elevator door clutch scrapes fascia when running up. Check guide rails for adjustment.
|
1/15/2021
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)3
|
|
|
First Floor Hoistway sill is bowed preventing unassisted closing of hoistway door
|
8/8/2022
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
Alarm bell in car does not work
|
8/8/2022
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
Machine Room is not to contain any items not related to the operation of the elevator
|
8/8/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
x
|
|
A17.1 1984 Rule 110.11e - Hoistway door panels shall not have a gap larger than 3/8" between the door and frame.
|
8/15/2023
|