Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.5 - Housekeeping 1206.2b (Clean Machine Room) No No Materials not related to elev. operation stored in mach. room 6/3/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Remove drain tubes from jack heads, and provide a container for each jack, in pit, not to exceed 5 gallon capacity. 5/27/2026
MO Minimum : Elevators (I) - Pits (I)7 No No Pit switch not accessible from the landing. 5/27/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Provide pit jugs in pit, one for each jack not to exceed 5 gallon capacity each. 5/27/2026
MO Minimum : Elevators (I) - Pits (I)7 No No Provide an upper pit switch accessible from the lower landing. Existing switch too low from landing. 5/27/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not working. 5/9/2023
A17.1-1996 : Elevators 1.6 - Car emergency signal 1004.2(a)(6) (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not working, alarm bell ok.