Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion conversion - reinspect x Replace undersized wire ropes. 4/12/2019
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Category 5 test incomplete, perform the following tests to complete inspection: test car safeties at rated speed with rated load, test car buffer at rated speed with rated load, test counterweight buffer at rated speed, test brake with 125% of rated load, test governor switch and governor jaw tripping speed, test governor rope pull through and pull out force. Re-inspection required
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts x x Drive machine sheave liner is damaged and falling off traction sheave, needs repaired. Red-tagged and removed from service. Re-inspection required before use.