Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x All smokes and heat detectors must be tested when second car is finished. 8/21/2024
MO Minimum : Elevators (I) - Pits (I)1 Elevator pit needs to have oil removed 11/28/2022
MO Minimum : Elevators (I) - Pits (I)1 Need to clean pit 11/28/2022
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light is not working 11/28/2022
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits Clean elevator pit. 4/29/2020
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 1206.2a x Clean oil from elevator pit. 11/25/2019
A17.1-2016 : Elevators 1.13 - Emergency exit 2.14.1.5 x Drop ceiling does not allow access to emergency exit. Take corrective action as needed. Note: Car top emergency exit panel opens up to ceiling panel release latch. However, the whole back ceiling panel drops down for emergency exit, and the other ceiling panel release latch on the other end is under the car top with no access to it. Need to correct problem or apply for variance.
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8 x All electrical covers shall be installed at completion of second elevator. 8/21/2024
A17.1-1996 : Elevators 1.13 - Emergency exit 204.1e x Drop ceiling does not allow access to emergency exit. Take corrective action as needed. 1/13/2025
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.7 Firefighter' Service Operating Procedures Post Phase I instructions, near the f/f switch in the lobby. 12/5/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be on display in the machine room 11/28/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be on display in the elevator machine room 11/28/2022
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Written maintenance control program shall be kept on site for each elevator. 11/28/2022
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing OSV needs to be tested in 90 days or less 5/6/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Scavenger pump must be removed, cannot log amount of oil loss from packing gland 11/28/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Scavenger pumps that do not record the amount of oil returned to the hydraulic tank can not be installed. Either install recordable scavenger pump or limit the amount of oil stored in the pit to 5 gallons. 11/28/2022