A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Properly display current state operating certificate in the machine room.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures and monthly fire service testing records are missing. (This item is for notification purposes for future violation in 2022)
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and related on-site documentation shall be provided in the machine room. 2023 blank and no fire service logs present.
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Two-way communication device shall work with and without main power. (2nd Notice) Violation must be corrected immediately.
A17.1-1996 : Elevators 4.2 - Hoistway doors 110 x Replace missing hoistway door gibs (including but not limited to 2nd floor). (2nd Notice)
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
A17.1-1996 : Elevators 1.17 - Standby power operation 211.2 x Elevators that are equipped to operate on emergency power shall be tested with no load in the car while operating on the emergency generator.
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display a current MO state operating certificate.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Provide a code compliant MCP including on-site documents.
conversion conversion n/a Counterweight anti-rotation rope broken 11/2/2017
conversion conversion n/a No current state certificate posted. 11/2/2017
conversion conversion n/a Hoistway access switch at top landing did not work. 11/2/2017
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post curren State certiicate in machine room 3/18/2020
A17.1-1996 : Elevators 1.17 - Standby power operation 1001.2(a)(17) x Standby power operation of the elevators shall be tested. 4/8/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Two-way emergency communication shall be operational. 12/5/2022
A17.1-1996 : Elevators 1.17 - Standby power operation 211.2 x Elevators that are equipped to operate on emergency power shall be tested with no load in the car while operating on the emergency generator. 12/7/2023
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Two-way communication device shall work with and without main power. 11/18/2024
A17.1-1996 : Elevators 4.2 - Hoistway doors 110 x Replace missing hoistway door hanger secondary fire retainers (including but not limited to the 5th floor). 11/18/2024
A17.1-1996 : Elevators 4.2 - Hoistway doors 110 x Replace missing hoistway door gibs (including but not limited to 2nd floor). 11/18/2024