Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a No No Cab emergency lights do not work. 9/10/2020
conversion conversion n/a No No Alarm bell shall work. 9/10/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Replace missing bolt and nut on fishplate at top floor guide rail joint.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No Replace car roller guides where needed. 9/10/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No No A written copy of the MCP shall be kept in the machine room for each unit
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 8/25/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No Repair inoperative battery lowering device 4/22/2024