| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x |  | Emergency light in the cab does not work | 4/9/2024 | 
                
                    | A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x |  | Emergency light not working. | 11/20/2019 | 
                
                    | A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x |  | Emergency alarm bell not working. | 11/20/2019 | 
                
                    | A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x |  | Alarm bell does not work on 110v emergency power or normal power | 4/9/2024 | 
                
                    | A17.1-1996 : Elevators | 1.7 - Car door or gate | 1001.2(a)(7) |  | x | Adjust car door to cab clearance to 3/8 max - currently in excess of 1/2 inch. | 9/28/2020 | 
                
                    | A17.1-1996 : Elevators | 2.1 - Access to machine space | 1001.2(b)(1) |  |  | Machine room needs to be locked at all times. | 10/22/2019 | 
                
                    | A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h |  |  | Annual tag shows expired. | 11/30/2022 | 
                
                    | A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h |  |  | Provide current year tested fire extinguisher in the elevator machine room. |  | 
                
                    | A17.1-1996 : Elevators | 3.17 - Door and gate equipment | 1001.2(c)(23) |  |  | Replace missing door gibbs on 5th floor and missing fire tab on 3rd floor. | 9/28/2020 | 
                
                    | A17.1-1996 : Elevators | 3.17 - Door and gate equipment | 1001.2(c)(23) |  |  | Top level door is missing two door gibs. | 10/22/2019 | 
                
                    | A17.1-1996 : Elevators | 3.17 - Door and gate equipment | 210.1e |  |  | Gate switch exceeds minimum measurement for center opening doors. Reinspect. | 10/22/2019 | 
                
                    | A17.1-1996 : Elevators | 3.2 - Car top light and outlet | 204.7 |  |  | Provide car top light to work. |  | 
                
                    | A17.1-1996 : Elevators | 3.8 - Top emergency exit | 204.1e |  |  | Provide means to secure car top exit. |  | 
                
                    | A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) |  |  | There needs to be a working lit in the pit. | 10/22/2019 | 
                
                    | A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits |  |  | Provide existing pit light to work. |  | 
                
                    | A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | x |  | Provide,on Phase II operations, call cancel feature to work. | 4/17/2025 | 
                
                    | conversion | conversion | n/a |  |  | Post Mo Stae certificate in machine room | 10/22/2019 | 
                
                    | A17.1-1996 : Elevators | CSR  40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate |  |  | Post current operating certificate in machine room. | 10/22/2019 | 
                
                    | A17.1-1996 : Elevators | CSR  40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate |  |  | Post current operating certificate in machine room. | 10/22/2019 |