Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency light not working. 11/20/2019
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency alarm bell not working. 11/20/2019
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) Yes No Emergency light in the cab does not work 4/9/2024
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1002.2f Yes No Provide,on Phase II operations, call cancel feature to work. 4/17/2025
A17.1-1996 : Elevators 1.12 - Car enclosure 1202.5 Yes No Observed tile floor needs to be secured down or replaced.
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits No No Provide existing pit light to work. 3/13/2026
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1206.1h No No Provide current year tested fire extinguisher in the elevator machine room. 3/13/2026
A17.1-1996 : Elevators 3.2 - Car top light and outlet 204.7 No No Provide car top light to work. 3/13/2026
A17.1-1996 : Elevators 3.8 - Top emergency exit 204.1e No No Provide means to secure car top exit. 3/13/2026
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current operating certificate in machine room. 10/22/2019
A17.1-1996 : Elevators 1.7 - Car door or gate 1001.2(a)(7) No Yes Adjust car door to cab clearance to 3/8 max - currently in excess of 1/2 inch. 9/28/2020
A17.1-1996 : Elevators 3.17 - Door and gate equipment 1001.2(c)(23) No No Replace missing door gibbs on 5th floor and missing fire tab on 3rd floor. 9/28/2020
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1206.1h No No Annual tag shows expired. 11/30/2022
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current operating certificate in machine room. 10/22/2019
A17.1-1996 : Elevators 2.1 - Access to machine space 1001.2(b)(1) No No Machine room needs to be locked at all times. 10/22/2019
A17.1-1996 : Elevators 3.17 - Door and gate equipment 1001.2(c)(23) No No Top level door is missing two door gibs. 10/22/2019
A17.1-1996 : Elevators 3.17 - Door and gate equipment 210.1e No No Gate switch exceeds minimum measurement for center opening doors. Reinspect. 10/22/2019
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 1206.2a (Pits and Hoistways) No No There needs to be a working lit in the pit. 10/22/2019
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Alarm bell does not work on 110v emergency power or normal power 4/9/2024
conversion conversion n/a No No Post Mo Stae certificate in machine room 10/22/2019