Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(G)
|
|
x
|
Skirt indexing could not be completed due to separating skirt panels. Skirt indexing test shall be completed.
|
8/27/2018
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.1.4 Maintenance Records
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
4/1/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
Escalator driving machine brake shall be provided with a data plate that is readily visible, located on the machine brake.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
x
|
|
The escalator step/skirt performance index shall be less than or equal to 0.4
|
10/25/2021
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Step indexing failed. Loaded gap value is more than .4.
|
8/11/2022
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Step index testing needs to be completed.
|
6/29/2023
|