Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Escalators 7.5 - Lighting 1009.2d all steps and landings measure less than 5fc 12/4/2018
A17.1-1996 : Escalators 7.5 - Lighting 805.7 demarcation lights not working 12/4/2018
A17.1-1996 : Escalators 7.7 - Combplate and comb step impact device 802.6 802.6a(2) combplates-some teeth broken need replaced 12/4/2018
A17.1-2016 : Elevators 9.19 - Maintenance Records 8.6.1.2.1(a) No maintenance records 4/1/2024
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate Provide current state operating certificate 7/15/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.7 - Combplate and comb step impact device 8.6.8.4 Combplates Provide undamaged comb plates at each landing 7/15/2024
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate Provide current state operating certificate
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.7 - Combplate and comb step impact device 8.6.8.4 Combplates Provide undamaged comb plates, upper and lower
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.2 Escalator Step-to-Skirt Clearance x Skirt indexing test did not pass , suggest adding brushes on this unit 10/26/2023