A17.1-1996 : Escalators
|
7.7 - Combplate and comb step impact device
|
802.6
|
|
|
802.6a(2) combplates-some teeth broken need replaced
|
12/4/2018
|
A17.1-1996 : Escalators
|
7.5 - Lighting
|
1009.2d
|
|
|
all steps and landings measure less than 5fc
|
12/4/2018
|
A17.1-1996 : Escalators
|
7.5 - Lighting
|
805.7
|
|
|
demarcation lights not working
|
12/4/2018
|
A17.1-2016 : Elevators
|
9.19 - Maintenance Records
|
8.6.1.2.1(a)
|
|
|
No maintenance records
|
4/1/2024
|
Missouri Minimum : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
Provide current state operating certificate
|
7/15/2024
|
Missouri Minimum : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
Provide current state operating certificate
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.7 - Combplate and comb step impact device
|
8.6.8.4 Combplates
|
|
|
Provide undamaged comb plates at each landing
|
7/15/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.7 - Combplate and comb step impact device
|
8.6.8.4 Combplates
|
|
|
Provide undamaged comb plates, upper and lower
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
x
|
|
Skirt indexing test did not pass , suggest adding brushes on this unit
|