MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: The visual signal device did not light in the car when phase I was activated. Reinspection required. 3/12/2021
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Govenor rope shall be replaced due to rusting. Re-inspection required 3/21/2022
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor. 3/8/2019
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor. 2/21/2020
MO Minimum : Elevators (I) - Pits (I)1 The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. 2/21/2020
MO Minimum : Elevators (I) - Pits (I)1 The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. 3/8/2019
MO Minimum : Elevators (I) - Pits (I)1 The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. 3/21/2021
MO Minimum : Elevators (F) - Electrical Switches (F)2 x The final and normal limit switches shall be adjusted to operate for proper run-by of the counterweight and buffer. Reinspection required. 3/12/2021