MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
post emergency evacuation of passengers procedure form inside machine room.
|
3/15/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
hall firefighter keyswitch identification markings are illegible. "on-off-byp"
|
3/15/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.9 Cleaning of Top of Cars
|
|
|
clean debris from top of car and remove oil cans.
|
3/15/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.5.5.2 Oil Leakage Collection
|
|
|
cylinder drain needs to be removed from hydraulic tank and ran to container in pit not to exceed 5 gallons.
|
3/15/2021
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
remove rags and absorbent pads from machine room floor.
|
3/15/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.2.1 General Maintenance Requirements Documentation
|
|
|
No maintenance control plan on site
|
3/21/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
No maintenance records on site
|
3/21/2023
|
conversion
|
conversion
|
n/a
|
|
|
audible signal does not operate on fire service phase 1 operation.
|
8/5/2019
|
MO Minimum : Elevators
|
(O) - Existing Hydraulic Elevators
|
(O)2(B)
|
|
|
Perform full load pressure test and seal relief pressure setting with inspector present. The hydraulic control /relief valve has been replaced.
|
2/13/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
Post In Case of Fire signage next to hall button fixture
|
11/2/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Door Systems 8.6.4.13 (Re-Inspection)
|
x
|
|
install cover over exposed 110 volt wiring on car door operator.
|
4/12/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
|
emergency light and bell do not operate.
|
4/12/2021
|
MO Minimum : Elevators
|
(O) - Existing Hydraulic Elevators
|
(O)4 (Re-Inspection)
|
x
|
|
Repair or replace hydraulic control valve. Elevator drifts down 3 inches in 15 minutes unless hydraulic line shut off is closed.
|
1/13/2023
|