Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Adjust door restrictor for proper operation. 12/11/2024
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Repair inoperative emergency light. 1/28/2019
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Complete Cat 5 testing by striking the car and counterweight buffers at contract speed 12/11/2024
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.2-211.8 x x Change fire recall bezel to 3 position: Off, Hold, On - Did NOT red tag the elevator. 8/6/2019
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)12 x Stop switch shall be overridden during Phase I recall. 30 day reinspection required. 9/30/2020