MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Repair inoperative emergency phone
|
8/22/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.32 - Control Valve
|
8.11.3.1.2 (o)
|
x
|
|
Repair and replace control. Valve is leaking excessively.
|
5/17/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
4.2 - Hoistway doors
|
8.6.4.13
|
x
|
|
A numerous amount of fire retaining tabs are missing on each hoistway door. The fire retaining tabs shall be replaced.
|
8/29/2024
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.3.2 Phase I Operation Recall by Initiating Device
|
x
|
x
|
FAID testing failed to operate under the requirements of A17.1 2016. Initiating devices shall be repaired and pre-tested prior to reinspection.
|
8/29/2024
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Door closing force above 30 lbs on both card doors
|
5/14/2019
|
conversion
|
conversion
|
n/a
|
|
|
Clean pit of oil and debris
|
10/13/2019
|