conversion
|
conversion
|
n/a
|
|
|
Clean the trash out of the pit, it is a fire hazard.
|
10/17/2018
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Clean up the excessive debris in the pit as it is a fire hazard.
|
10/17/2018
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Obtainand display a current state operating certificate in the machine room
|
10/6/2020
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Clean the debris out of the pit , it is a fire hazard.
|
10/6/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Repair or replace the emergency phone as it does not work.
|
6/27/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
Replace the emergency alarm bell battery. It will not ring.
|
6/27/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.5.5.1 Examination and Maintenance
|
|
|
Repace the jack seals as the pit bucket has to be emptied every time a service man is on site per the record oil log.
|
7/5/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.11.1 Firefighters' Emergency Operation & Documentation
|
|
|
Repair the emergency fire service as phase 1 will not recall the elevator if it is in flight it goes to the 2nd. floor and opens the doors. Phase 1 is to recall the elevator to the first or primary landing and open the doors.
|
7/5/2023
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
Replace the burnt out light s in the car ceiling
|
7/5/2023
|