Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Replace the burnt out light s in the car ceiling 7/5/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Repair or replace the emergency phone as it does not work. 6/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Replace the emergency alarm bell battery. It will not ring. 6/27/2023
MO Minimum : Elevators (I) - Pits (I)1 Clean up the excessive debris in the pit as it is a fire hazard. 10/17/2018
MO Minimum : Elevators (I) - Pits (I)1 Clean the debris out of the pit , it is a fire hazard. 10/6/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtainand display a current state operating certificate in the machine room 10/6/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.11.1 Firefighters' Emergency Operation & Documentation Repair the emergency fire service as phase 1 will not recall the elevator if it is in flight it goes to the 2nd. floor and opens the doors. Phase 1 is to recall the elevator to the first or primary landing and open the doors. 7/5/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance Repace the jack seals as the pit bucket has to be emptied every time a service man is on site per the record oil log. 7/5/2023
conversion conversion n/a Clean the trash out of the pit, it is a fire hazard. 10/17/2018