Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a emergency light and bell do not work 10/29/2018
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.11.1 Firefighters' Emergency Operation & Documentation Post emergency evacuation of passengers procedure inside machine 11/17/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.11.1 Firefighters' Emergency Operation & Documentation Test and log firefighter operation monthly 11/17/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Cylinder drain lines need to drain into pit collection containers of no more than 5 gallons 11/17/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room access door needs to be self-locking 12/18/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Cylinder drain lines need to drain into pit collection containers 12/18/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state operating certificate inside the machine room 12/18/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room access door needs to be self-locking and non-defeatable 12/18/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Maintenance record log not up to date 12/18/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Cylinder drain lines shall be ran to pit collection container, not back to hydraulic tank. 12/18/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate not displayed 12/18/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room access door needs to be self-closing and self-locking. (third notice) 12/14/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Cylinder drain lines need to be ran to pit collection containers. (third notice) 12/14/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate not displayed 12/14/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency light does not operate 2/5/2024