Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (I) - Pits (I)1 oil in pit
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)2(B) relife valve pressure too high
A17.1-2016 : Elevators 1.15 - sign and operating device symbols 8.6.1.6.7 fire serv bezels in hall an car not readable
MO Minimum : Elevators (I) - Pits (I)1 oil in pit needs to be cleaned
A17.1-2016 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.14.2 leak dn test failed red tagged 1/20/2021
A17.1-2016 : Elevators 3.8 - Top emergency exit 2.14.1.5 x the escape hatch hits the box installed on the crosshead preventing the escape hatch from fully opening 5/21/2021
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.1 Emergency communications and alarm not functioning (Red Tag) x the emergency phone was not answered 5/21/2021