Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Need to perform the following tests to complete 5 yr inspection: counterweight buffer, counterweight safeties, car buffer, car safeties, 125% brake, both car & counterweight governor pull outs, pull thru's, speed switches & jaws. Re-inspection required 12/13/2023
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)12 x Test Fireman's recall 10/29/2019
A17.1-1996 : Elevators 5.10 - Compensating chains, ropes, and sheaves 1001.2(e)(8) x Shorten compensating ropes. 1/22/2021
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Emergency light not working. 2/24/2020
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x Emergency light shall work. 2/10/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Fire extinguisher in machine room is expired, have serviced or replaced.