Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.1.4 Maintenance Records
|
|
|
Provide written maintenance control program to include wiring diagrams to be kept on site.
|
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.13 Escalator Cleaning
|
|
|
Perform unit clean down and repair seals causing oil leak on steps.
|
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(E)
|
|
|
Top right comb plate has 2 missing teeth, needs replaced
|
|
|
Missouri Minimum : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
Post current certificate
|
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A copy of the current state operating certificate shall be displayed in the machine room
|
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.13 Escalator Cleaning
|
|
|
Perform complete clean down to remove oil leaking from drive machine.
|
|
|
MO Minimum : Elevators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
T(1) 704 Driving Machines and Sheaves
|
|
|
Need to replace leaking seal on drive machine.
|
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.11.4.2.13 Escalator Handrail Safety Systems
|
x
|
|
Provide Category 1 testing.of handrail
|
9/20/2022
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Provide Category 1 testing.of step/ skirt index
|
9/20/2022
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(A)
|
x
|
|
Provide Category 1 testing.of brake torque.
|
9/20/2022
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.4 Escalator Combplates
|
x
|
|
Provide Category 1 testing, lower center comb.
|
9/20/2022
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.14 Escalator Entrance and Egress Ends
|
x
|
x
|
Screws broken off upper center comb plate during testing, unit removed from service.
|