Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Elevator machine room cannot be used for storage of non-elevator equipment. 4/9/2026
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No Elevator machine room cannot be used for storage of non-elevator equipment. Remove all non elevator related materials from machine room
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No Elevator machine room cannot be used for storage. 4/9/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Emergency light & bell are not working. Re-inspection required 4/9/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Fire extinguisher in machine room is expired, have serviced or replaced
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)1 Yes Yes Full load car safety test failed due to governor jaw malfunction. Repair governor jaws and retest pull through force and perform car safety test with full load. Elevator red-tagged until repair is made and reinspected. 2/5/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door shall be self closing and self locking
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No No MCP is not filled out, including monthly fire service checks
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Replace all missing braille plates on hoistway door jambs as needed
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Replace deteriorated bushings on cartop hoist rope shackle hitch
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No Written maintenance control program shall be provided on-site. 4/9/2026