Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)2 Elevator machine room cannot be used for storage of non-elevator equipment.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Written maintenance control program shall be provided on-site.
MO Minimum : Elevators (H) - Machine Rooms (H)4 Elevator machine room cannot be used for storage.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency light & bell are not working. Re-inspection required
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)1 x x Full load car safety test failed due to governor jaw malfunction. Repair governor jaws and retest pull through force and perform car safety test with full load. Elevator red-tagged until repair is made and reinspected. 2/5/2021